DP-F and DP-N amps are made for your big line array!
With just 3 pcs of DP-4100F or DP-4100N……massive systems can be created.
SPECIFICATIONS
| Model |
DP-4065F |
| Rated Power (THD=1%,Each channel works simultaneously with continuous sinusoidal 1 KHz) |
8 Ω / Stereo |
4 x 650 W |
|
4 Ω / Stereo |
4 x 1100 W |
|
2 Ω / Stereo |
4 x 1870 W |
|
16 Ω / Bridge |
2 x 1300 W |
|
8 Ω / Bridge |
2 x 2200 W |
|
4 Ω / Bridge |
2 x 3740 W |
|
100 V Hi-Z |
– |
|
70 V Hi-Z |
4 x 1100 W |
| Output RMS voltage |
|
72.1 V |
| Maximum Input Level |
|
8.7 Vrms(+21 dBu)(Default Gain) |
| Default Gain (Rated Power,1 KHz) |
|
19 dB |
| Gain(Rated Power,1 KHz) |
|
19 dB~37 dB |
| THD+N |
|
Typical value:0.05%(10% Rated Power,8 Ω) |
| Cross-Talk |
|
≥90 dB(20 Hz-1 KHz,Below Rated Power,8 Ω) |
| Frequency Response |
|
Typical value:+0,-0.5 dB(10% Rated Power,20 Hz-20 KHz,8 Ω) |
| Input Impedance |
|
20 kΩ(Balance),10 kΩ(Unbalance) |
| Damping Factor |
|
≥1000(20 Hz-200 Hz,8 Ω) |
| SNR |
|
≥105 dB (Default Gain, A weighted,20 Hz-20 KHz,8 Ω) |
| Main Power |
|
90~260 VAC,50/60 Hz |
| Protection |
|
Power under-voltage protection、Amplifier output DC protection、Thermal Protection Temperature Power Control、Overload Power Control |
| Size(W×H×D) |
|
483 x 45 x 376 mm |
| Net Weight |
|
9.1 kg |
WP DP-F user manual 20220323 (wharfedalepro.com)
Please Note: Shipping quoted is an estimate only. We will contact you with a quote for actual shipping charges to your location if necessary.